MIFAB® Series MC-15 single, vertical, fixed, water closet carrier with offset lacquered cast iron fitting, 4” (102) no hub waste, 2” (51) no hub vent connection, lacquered cast iron faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support. |
No Rating |
Product Version: Unknown
16 Downloads
|
|
 |
Series LF53L Lead Free* Poppet Type Pressure Relief Valves are used for protection against excessive pressure on domestic storage tanks or tankless water heaters. Model LF53L has the same basic design as Model LF3L except it is furnished in 1/2 in. (15mm) size and does not comply with ASME requirements. Pressure range is 75-150psi (5.2-10.3 bar). Series LF53L comes in standard settings of 75, 100, 125 and 150psi (5.2, 6.9, 8.6 and 10.3 bar). These pressure relief valves are popularly used in conjunction with the Model LF210 gas shutoff valve on gas water heaters to shut off gas to heater if water heater temperature exceeds 210 degreeF (99 degreeC). The LF53L features Lead Free* construction to comply with Lead Free* installation requirements. |
No Rating |
Product Version: Revit MEP 2014
341 Downloads
|
|
 |
Series CA-421 floor mounted plate type lavatory or water cooler carrier with heavy gauge steel uprights with integral welded feet, universal steel hanger support plate, and plated hardware. |
No Rating |
Product Version: Revit MEP 2014
155 Downloads
|
|
 |
Series SS009 Stainless Steel Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. They have a stainless steel body construction, two stainless steel check valves, stainless steel check seats, hydraulically-operated relief valve, and stainless steel, vandal-resistant ball valve test cocks. Series SS009 is ideal in applications where the downstream liquid is of a composition where bronze material would be damaged or if it is desirable to eliminate trace elements of lead and copper. Series SS009 is ideal in industrial or plant applications, in medical/diagnostic equipment, in reverse osmosis systems, and for other health hazard piping systems. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar) |
No Rating |
Product Version: Revit MEP 2014
474 Downloads
|
|
 |
Series 719 Double Check Valve Assemblies are designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements. They have a bronze alloy body construction and chloramine resistant elastomers. Series 719 features a separate access, top-entry check valve design for ease of maintenance and is for use at referenced cross-connections in non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
310 Downloads
|
|
 |
Undermount sink. Width, Front-to-Back, and Depth dimensions are parametric.Nested faucet family includes modeled vacuum breaker. Gooseneck outlet spread has four built-in types to control dimension. Typical for the industry.
Sink "cuts" the countertop. Match up thickness of cutting void with thickness of top.
Useful for quick presentations of "what the lab looks like". |

|
Product Version: Revit Architecture 2017
15345 Downloads
|
|
 |
MIFAB® Series MC-10 (Specify -L for left or -R for right design) single, horizontal, adjustable, water closet carrier with lacquered cast iron fitting, 4” (102) no hub waste, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear
anchor tie down support. |
No Rating |
Product Version: Unknown
55 Downloads
|
|
 |
MIFAB® Series MC-10D-HS double, horizontal, adjustable hub and spigot water closet carrier with lacquered cast iron fitting, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
17 Downloads
|
|
 |
Series LF709 Lead Free* Double Check Valve Assemblies prevent the reverse flow of polluted water from entering into the potable water supply. They have a modular check design for easy maintenance and epoxy coated (FDA approved) cast iron body construction. Series LF709 is ideal at referenced cross-connections identified in non-health hazard applications. The LF709 features Lead Free* construction to comply with Lead Free* installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
349 Downloads
|
|
 |
Series 957RPDA, 957NRPDDA, 957ZRPDA Reduced Pressure Detector Assemblies prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 957RPDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of a compact, stainless steel body with stainless steel internal parts, two check valves, a pressure-differential relief valve, shutoff valves, torsion spring checks and relief valve, and bronze, nickel-plated test cocks. Series 957RPDA, 957NRPDDA, 957ZRPDA is 70% lighter than traditional designs and is ideal for health hazard cross-connection, such as on fire sprinkler systems. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
354 Downloads
|
|
 |
Series LF719 Double Check Valve Assemblies are designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements. They have a Lead Free* cast copper silicon alloy body construction and chloramine resistant elastomers. Series LF719 features a separate access, top-entry check valve design for ease of maintenance and is for use at referenced cross-connections in non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
132 Downloads
|
|
 |
Simple swimming pool w/ adjustable terrace and size (parametric). Also adjustable water level, pool depth, terrace dimensions for each side, thickness etc... as well as if the water should be visible (yes/no).
This is my first made family so please be kind :-) !!!
I Will include the material (there are 2 but I am not sure if can include those). Will try |
No Rating |
Product Version: Revit Architecture 2015
4611 Downloads
|
|
 |
Series 757DCDA, 757NDCDA Double Check Detector Assemblies prevent the backflow of pollutants that are objectionable but not toxic, from entering into the potable water supply. Compact housings consist of two independently operating tri-link check valves, two shutoff valves, and four test cocks. They feature a stainless steel housing and sleeve and are 70% lighter than traditional designs. Series 757, 757N is designed for non-health hazard applications and may be installed under continuous pressure service to protect against both backpressure and backsiphonage. This Series is used primarily on fire sprinkler lines when it is necessary to monitor unauthorized use of water. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
563 Downloads
|
|
 |
Series 9D Dual Check Valves with Intermediate Atmospheric Vent prevent the reverse flow of hot or cold polluted water from entering into the potable water supply. They have a brass body with stainless steel internal parts, integral strainer, and two durable, tight-sealing, rubber check valves. Series 9D is designed for continuous pressure, non-health hazard applications in smaller supply lines, such as laboratory equipment, processing tanks, sterilizers, dairy equipment, and specifically for boiler feed lines. Minimum Working Pressure: 25psi (172kPa), Maximum Working Pressure: 175psi (12.1 bar) |
No Rating |
Product Version: Revit MEP 2014
227 Downloads
|
|
 |
Filtrine Model FCC-107-14-HL fountain/chiller/purifier combination unit. Comes with a discrete and energy-saving chiller/purifier in the wall below. The chiller stores (2) gallons of chilled/purified Filtrine water (serving a population of 150). Matching key-lock, hinged access door provides chiller/purifier access and security. Architectural alternative to traditional Electric Water Cooler (EWC).
|
No Rating |
Product Version: Revit Architecture 2012
9620 Downloads
|
|
 |
Rinnai VT26 gas califont, wall based.
MEP connections for gas supply, cold water IN, hot water OUT, 230 v electrical power supply, no condensate drain (optional on this model), materials for white spray painted metal case, manufacturer logo, copper tubing.
CBI (NZ) Liquid 71-26 hot potable water reticulation systems
Has local NZ gas regulations module placement on wall relative to window or doors, dowpipes, balconies, internal corners and ground lines as diagram with Yes/No parameter control - place the unit on the wall and the unit and diagram appear, move to suit the annotated lines until module in correct place, click then select Properties and turn off the 2D diagram, leaving the module alone on the wall.
Modeled from local NZ Rinnai web site literature.
Revit 2018 |

|
Product Version: Unknown
588 Downloads
|
|
 |
Series FD-880 epoxy coated cast iron ground water containment drain with membrane clamp, 4 in. (102) diameter ABS perforated standpipe, ground level area drain with 8in. (203) diameter fixed top with heel proof ductile iron grate, and no hub (standard) outlet. |
No Rating |
Product Version: Revit MEP 2014
96 Downloads
|
|
 |
Series LF800M4FR Lead Free* Freeze Resistant Pressure Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage. It consists of Lead Free* Cast Copper Silicon Alloy body construction, silicone rubber check valve disc, plastic check valve seat, stainless steel springs, a bonnet with silicone rubber O-ring seal, a lightweight plastic disc float, a built-in relief valve to protect the internal components and the body from freezing, tee handle or lever handle shutoffs, and test cocks for winterization draining. Series LF800M4FR is ideal in continuous pressure health hazard applications where exposure to sudden freezing conditions such as on irrigation systems and industrial process water systems can occur. Maximum Pressure: 150psi (10.3 bar), Minimum Pressure: 15psi (55kPa). |
No Rating |
Product Version: Revit MEP 2014
212 Downloads
|
|
 |
Plastic water butt. Non Parametric |
No Rating |
Product Version: Revit Architecture 2009
963 Downloads
|
|
 |
The LF8 Series Hose Connection Vacuum Breakers permit the attachment of portable hoses to hose thread faucets and prevent the reverse flow of polluted water into the potable water supply due to backsiphonage. They have a copper silicon alloy body construction, stainless steel working parts, and a rubber diaphragm and disc. The LF8 Series is ideal for inside or outside health hazard installations requiring non-continuous pressure such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas, and general outside gardening uses. Check with local inspection authorities for installation requirements. Maximum Pressure:125psi (8.6 bar). |
No Rating |
Product Version: Revit MEP 2014
235 Downloads
|
|
 |
Series LF289 Spill Resistant Atmospheric Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage. They have a Lead Free* copper silicon alloy (LF289) body, silicone rubber check disc, stainless steel springs, a lightweight plastic disc float that minimizes deposits and scaling, a spring-loaded atmospheric vent with O-ring, and a spill-resistant diaphragm seal. Series LF289 has a compact, space-saving design, and is ideal for health hazard applications such as on chemical dispensers or factory machine equipment. Maximum Pressure:150psi (10.34 bar), Minimum Pressure: 8psi (.55 bar). |
No Rating |
Product Version: Revit MEP 2014
114 Downloads
|
|
 |
ADJUSTABLE WATER TANK SIZE.
SMALLEST 1M X 1M X 1M |
No Rating |
Product Version: Revit Architecture 2016
1304 Downloads
|
|
 |
Made from concrete and has water in the bowl |
No Rating |
Product Version: Unknown
4582 Downloads
|
|
 |
cool looking water bottle made of metal
rate and comment please |
No Rating |
Product Version: Revit Architecture 2013
920 Downloads
|
|
 |
cool looking water bottle made of metal
rate and comment please |
No Rating |
Product Version: Revit Architecture 2013
470 Downloads
|
|
| |
Overhead water tank created in version 2022, parametric |

|
Product Version: Revit Architecture 2020
39 Downloads
|
|
 |
Roterra type rainwater collectors are made from the environmentally friendly material polyethylene (PE) and are intended to be buried in the ground.
Roterra 1400 rainwater collectors are available in sizes from 2,200 L to 3,300 L.
Revit Version 2023, 2024, 2025 |

|
Product Version: Unknown
149 Downloads
|
|
| |
Lap pool 75'2" long, 42' wide to accomodate 6 lanes. 9 foot deep-end, steeply slopes to 6 ' deep, then slowly slopes up to 3' deep shallow end. I've made the concrete walls for a pool of the above dimensions. Capped it with an Aluminum gutter. And filled the pool with the correct mass of water. Beware the water might not show up in your standard views becuase "mass" objects and families generally are hidden (thus you will need to tweak your visual settings, or unhide>category>mass). Also be sure to create your site around the pool extents, or excavate the necessary hole for placing the pool. If you simply put the pool on a pre-made site the site won't recognize the walls as retention and you will appear to have a pool full of dirt. |

|
Product Version: Unknown
16162 Downloads
|
|
 |
ROCA
Application space: Bath
Reference: 5A9743C00
Index: Home > Products > Faucets > Shower columns > Shower column
Style: Loft
Description: The avant-garde design and the technology blend together to create strong and high-quality elements. This design is a timeless, singular and unalterable style proposal with a refined finish and the originality of its contours fill every space with elegance, precision and distinction.
Faucet: Included
Finish: Chrome
Handshower: Included
Installation type: Wall-mounted
Minimum water pressure required(bar): 2
Mixer type: Twin lever
Number of water outlets: 2, Shower flexible supply hose included
Shower head function: Rain
Suitable for: Shower |

|
Product Version: Revit Architecture 2012
122581 Downloads
|
|
 |
Series LFWCV, LFWCVS Lead Free* Brass Swing Check Valves prevent reverse fluid flow in water and steam applications. The Series features metal-to-metal seal with either threaded NPT or solder end connections in sizes 1/2 to 1 in. (15 to 25mm). They provide low pressure drop and automatic closure when fluid flow is stopped. Maximum Pressure: 200psi (13.8 bar) WOG (non-shock), 125psi (8.6 bar) WSP |
No Rating |
Product Version: Revit MEP 2014
500 Downloads
|
|