The MI-100 is engineered for equal distribution of water to all ports. It’s the perfect solution to keep sewer gas from entering the building from seldom used floor drains. The MI-100 can be located anywhere in the water supply and is engineered to permit the building owner to adjust the frequency and amount of water delivery through a timer and stainless steel solenoid valve. A manifold ensures that a minimum of 2 ounces of water are delivered to every port over a twenty-four hour period. The unit must be mounted 12” above the finished floor for every 20’ of water supply line. The MI-100 can be installed with a cabinet cover. The system is capable of priming from 1 to 30 floor drain traps. The MI-100 is practical to serve many floor drain traps in infrequently used buildings such as convention centers and sports facilities. The MI-100 is made of lead free materials that touch water. |
No Rating |
Product Version: Unknown
191 Downloads
|
|
 |
MIFAB® Series MC-12-HS single, vertical, adjustable, hub and spigot water closet carrier with lacquered cast iron fitting, 2” (51) vent connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support. |
No Rating |
Product Version: Unknown
38 Downloads
|
|
 |
Series 709DCDA Double Check Detector Assemblies prevent backflow of non-health hazard fire protection system substances from being pumped or siphoned into the potable water supply. It incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. Its compact epoxy coated cast iron unibody and modular check design facilitate simple and easy installation and maintenance. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
542 Downloads
|
|
 |
Series 774 Double Check Valve Assemblies prevent the backflow of polluted water from entering into the potable water supply. They have a compact construction and short lay length, ideal for retrofit installations. They feature a lightweight stainless steel body and low head loss. Series 774 is ideal in applications identified by local authorities as non-health hazard. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
505 Downloads
|
|
 |
MIFAB® Series MC-10-HS (Specify -L for left or -R for right design) single, horizontal, adjustable hub and spigot water closet carrier with lacquered cast iron fitting, 2” (51) vent connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support. |
No Rating |
Product Version: Unknown
34 Downloads
|
|
 |
MIFAB Series MC-10D-EXT double, horizontal, adjustable high rough-in water closet carrier with lacquered cast iron fitting, 4" (102) no hub waste, 2" (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8" tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
50 Downloads
|
|
 |
MIFAB® Series MC-13-HS single, vertical, adjustable, hub and spigot water closet carrier with lacquered cast iron fitting, left, right or both (specify) 4” (102) side inlets, 2” (51) vent connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support. |
No Rating |
Product Version: Unknown
22 Downloads
|
|
 |
MIFAB® Series MC-12D-HS double, vertical, adjustable hub and spigot water closet carrier with lacquered cast iron fitting, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
24 Downloads
|
|
 |
Series 909RPDA Reduced Pressure Detector Assemblies prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 909RPDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of an epoxy-coated cast iron body with stainless steel trim, bronze gate valves, a pressure-differential relief valve, shutoff valves, and bronze ball-type test cocks. Series 909RPDA provides maximum flow at low pressure drop utilizing the "air-in/water-out" design principle for protection during emergency combined backsiphonage and backpressure conditions. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
639 Downloads
|
|
 |
MIFAB® Series MC-15D double, vertical, fixed water closet carrier with offset lacquered cast iron fitting, 4” (102) no hub waste, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
42 Downloads
|
|
 |
Series 994DCDA Reduced Pressure Detector Assemblies prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 994DCDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of a stainless steel body, stainless steel internal parts, thermoplastic check valves and a bottom-mounted relief valve. Series 994DCDA is half the weight of competitive designs, and its short lay length makes installation and maintenance simple and easy. It is ideal for installation on fire protection systems. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar) |
No Rating |
Product Version: Revit MEP 2014
337 Downloads
|
|
 |
Series LF7R Lead-free* Dual Check Valves prevent the reverse flow of liquids in a plumbing system from entering the drinking water supply where there is a non-health hazard. Designed for residential water system containment at the service entrance or individual outlets. They can be installed immediately downstream of the residential meter in a horizontal or vertical position. Replaceable compact plastic check modules. Available in a combination of inlet/outlet sizes and types, and thread and end connections. |
No Rating |
Product Version: Revit MEP 2014
103 Downloads
|
|
 |
MIFAB® Series MC-10D-27-37-HS double, horizontal, adjustable hub and spigot water closet carrier with lacquered, 37” (940) long barrel cast iron fitting, 2” (51) no hub vent connection, 2” (51) no hub auxiliary inlet connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
23 Downloads
|
|
 |
MIFAB® Series MC-10D-27-37-HS double, horizontal, adjustable hub and spigot water closet carrier with lacquered, 37” (940) long barrel cast iron fitting, 2” (51) no hub vent connection, 2” (51) no hub auxiliary inlet connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
16 Downloads
|
|
 |
MIFAB® Series MC-10-EXT (Specify L for left or R for right design) single, horizontal, adjustable, high rough-in water closet carrier with lacquered cast iron fitting, 4” (102) no hub waste, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support |
No Rating |
Product Version: Unknown
26 Downloads
|
|
 |
MIFAB® Series MC-10-27-37 (Specify L for left or R for right design) single, horizontal, adjustable, water closet carrier with lacquered, 37” (940) long barrel cast iron fitting, 4” (102) no hub waste, 2” (51) no hub vent connection, 2” (51) no hub auxiliary inlet connection, lacquered cast iron gasketed adjustable faceplate, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipple with integral test cap, neoprene bowl gasket, hardware, threaded rod protectors, polished chrome plated finishing cap nuts and rear anchor tie down support. |
No Rating |
Product Version: Unknown
20 Downloads
|
|
 |
Series CA-431-1 floor mounted bi-level water cooler carrier with heavy gauge steel uprights with integral welded feet, universal steel hanger support plate, and plated hardware. |
No Rating |
Product Version: Revit MEP 2014
179 Downloads
|
|
 |
Series 709DCDA Double Check Detector Assemblies prevent backflow of non-health hazard fire protection system substances from being pumped or siphoned into the potable water supply. They incorporate a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. Their compact epoxy coated cast iron unibody and modular check design facilitate simple and easy installation and maintenance. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
299 Downloads
|
|
 |
Series LF008PCQT Lead Free* Anti-Siphon, Spill-Resistant, Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage on indoor point-of-use applications. They have a Lead Free* cast copper silicon alloy body construction, thermoplastic check and float assembly valve, stainless steel springs, tee handles, and a molded diaphragm separating the air inlet from the potable water supply to prevent spillage. Series LF008PCQT is ideal for indoor use on machines or equipment in general plumbing applications. Maximum Working Pressure: 150psi (10.34 bar), Minimum Working Pressure: 8psi (55.2 kPa). |
No Rating |
Product Version: Revit MEP 2014
184 Downloads
|
|
 |
MIFAB® Series MC-13D-HS double, vertical, adjustable hub and spigot water closet carrier with lacquered cast iron fitting, left, right or both (specify) 4” (102) side inlets, 4” (102) no hub waste, 2” (51) no hub vent connection, lacquered cast iron gasketed adjustable faceplates, universal floor mounted cast iron foot supports, adjustable 8” tapered thread ABS nipples with integral test caps, neoprene bowl gaskets, hardware, threaded rod protectors and polished chrome plated finishing cap nuts. |
No Rating |
Product Version: Unknown
19 Downloads
|
|
 |
Modeled directly from real world example.
Finishes (RAC 2009, mental ray materials) ; white plastic case, black plastic ribbon strips, clear acrylic tank window, water in tank, stainless steel tray insert.
Adjustments etc: adjustable water height in tank, red LED lights for ON/OFF switches when rendered. |

|
Product Version: Revit Architecture 2009
21106 Downloads
|
|
 |
Series U009 Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. They have a bronze body construction with a unique swivel union, two in-line independently operating check valves, a removable stainless-steel relief valve with captured springs and replaceable seat discs, four ball valve test cocks, and an air gap drain fitting. Their compact and space-saving design facilitates easy assembly and maintenance access. They are ideal for protection at health hazard cross-connections or for containment at the service line entrance. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
239 Downloads
|
|
 |
Series LFN9, LFN9C Lead Free* Dual Check Vacuum Breakers prevent the reverse flow of polluted water from entering into the potable water supply. They have a Lead Free* brass body construction with an atmospheric vent, and NPT female inlet and outlet connections. Series LFN9 and LFN9C are designed for non-health hazard, continuous pressure applications. Series LFN9C comes with chrome plated finish. Maximum Working Pressure: 125psi (8.6 bar) |
No Rating |
Product Version: Revit MEP 2014
78 Downloads
|
|
 |
Series LF40L, LF40XL Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a Lead Free* brass body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model LF40L has a short thermostat for installation directly in available tank tapings. Model LF40XL has an extension thermostat for installation in the hot water outlet within the allowable distance from the top of the tank. Series LF40L, LF40XL valves are ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
173 Downloads
|
|
 |
Series LFLL40XL, LFLLL40XL Extended Shank Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature an extended shank for installation on water heaters with extra thick insulation as well as a Lead Free* cast copper silicon alloy with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model LFLL40XL is available in sizes 3/4 and 1 in. (20 and 25mm). Model LFLLL40XL is available in size 3/4 (20mm) with an extra long extended shank. Series LFLL40L, LFLLL40XL valves are ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
89 Downloads
|
|
 |
Series RD-100-R epoxy coated cast iron overflow roof drain with flashing clamp with integral 2 in. (51mm) high external water dam, self-locking polyethylene dome (standard), and no hub (standard) outlet. |
No Rating |
Product Version: Revit Structure 2014
192 Downloads
|
|
 |
Series RD-200-R epoxy coated cast iron overflow roof drain with flashing clamp with integral 2 in. (51mm) high external water dam, self locking polyethylene dome (standard), and no hub (standard) outlet. |
No Rating |
Product Version: Revit Structure 2014
121 Downloads
|
|
 |
Larger, wall based unit. Size of the box which is embedded in the wall 5" is 18" x 12" x 6". The heating unit is embedded inside of the box. It has two small valve extrusions on the bottom that appear to run through the bottom of the box. |
No Rating |
Product Version: Revit Architecture 2011
5011 Downloads
|
|
 |
Series RD-300-R epoxy coated cast iron overflow roof drain with flashing clamp with integral 2 in H2199(51mm) high external water dam, self-locking polyethylene dome (standard), and no hub (standard) outlet. |
No Rating |
Product Version: Revit MEP 2014
128 Downloads
|
|
 |
Simple swimming pool w/ adjustable terrace and size (parametric). Also adjustable water level, pool depth, terrace dimensions for each side, thickness etc... as well as if the water should be visible (yes/no).
This is my first made family so please be kind :-) !!! |

|