Series 719 Double Check Valve Assemblies are designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements. They have a bronze alloy body construction and chloramine resistant elastomers. Series 719 features a separate access, top-entry check valve design for ease of maintenance and is for use at referenced cross-connections in non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
312 Downloads
|
|
 |
Series LF709 Lead Free* Double Check Valve Assemblies prevent the reverse flow of polluted water from entering into the potable water supply. They have a modular check design for easy maintenance and epoxy coated (FDA approved) cast iron body construction. Series LF709 is ideal at referenced cross-connections identified in non-health hazard applications. The LF709 features Lead Free* construction to comply with Lead Free* installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
354 Downloads
|
|
 |
Series 009 Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. They have a bronze body construction (1/4 to 2 in.) or FDA approved epoxy coated cast iron (2 1/2 to 3 in.), two in-line independent check valves, replaceable check seats with an intermediate relief valve, and ball valve test cocks. Series 009 is ideal for protection of health hazard cross-connections or for containment at the service line entrance. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
343 Downloads
|
|
 |
Series 009 Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. It consists of bronze body construction (1/4 to 2 in., 8 to 50mm) or FDA approved epoxy coated cast iron (2 1/2 to 3 in., 65 to 80mm), two, in-line independent check valves, replaceable check seats with an intermediate relief valve, and ball valve test cocks. Series 009 is ideal for protection of health hazard cross-connections or for containment at the service line entrance. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
435 Downloads
|
|
 |
Series 919 Reduced Pressure Zone Assemblies prevent the reverse flow of contaminated water from entering into the potable water supply due to backsiphonage and or backpressure. They have a bronze body construction, two poppet style check valves, and replaceable check seats, with an intermediate relief valve. Series 919 compact modular design facilitates easy maintenance and assembly access. It is ideal for protection at health hazard cross-connections or for containment at the service line entrance. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit Structure 2014
119 Downloads
|
|
 |
Series 774DCDA Double Check Detector Assemblies prevent the backflow of fire protection system substances from being pumped or siphoned into the potable water supply. They have a compact construction and short lay length, ideal for retrofit installations. They feature a lightweight stainless steel body, thermoplastic and stainless steel check valves, and low head loss. Series 774DCDA can be installed in the horizontal or vertical flow-up positions. It is designed for installation on applications identified by local authorities as non-health hazard, such as on fire protection systems. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
608 Downloads
|
|
 |
Series LF719 Double Check Valve Assemblies are designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements. They have a Lead Free* cast copper silicon alloy body construction and chloramine resistant elastomers. Series LF719 features a separate access, top-entry check valve design for ease of maintenance and is for use at referenced cross-connections in non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
132 Downloads
|
|
 |
Series 757DCDA, 757NDCDA Double Check Detector Assemblies prevent the backflow of pollutants that are objectionable but not toxic, from entering into the potable water supply. Compact housings consist of two independently operating tri-link check valves, two shutoff valves, and four test cocks. They feature a stainless steel housing and sleeve and are 70% lighter than traditional designs. Series 757, 757N is designed for non-health hazard applications and may be installed under continuous pressure service to protect against both backpressure and backsiphonage. This Series is used primarily on fire sprinkler lines when it is necessary to monitor unauthorized use of water. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
569 Downloads
|
|
 |
Series 9D Dual Check Valves with Intermediate Atmospheric Vent prevent the reverse flow of hot or cold polluted water from entering into the potable water supply. They have a brass body with stainless steel internal parts, integral strainer, and two durable, tight-sealing, rubber check valves. Series 9D is designed for continuous pressure, non-health hazard applications in smaller supply lines, such as laboratory equipment, processing tanks, sterilizers, dairy equipment, and specifically for boiler feed lines. Minimum Working Pressure: 25psi (172kPa), Maximum Working Pressure: 175psi (12.1 bar) |
No Rating |
Product Version: Revit MEP 2014
231 Downloads
|
|
 |
Series 994 Reduced Pressure Zone Assemblies prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. It consists of a stainless steel body construction with stainless steel internal parts. The bottom-mounted relief valve is located between the two check valves, making it suitable for installations against an outside wall. Series 994 has a compact design with a short lay length, ideal for retrofit installations. The 994 is designed for health hazard applications. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
238 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |

|
Product Version: Revit Architecture 2015
6097 Downloads
|
|
 |
MIFAB® MI-LINT Series sanitary powder epoxy coated inside and outside fabricated 10 gauge steel lint interceptor with flow rate of 34-1536 gpm. Unit shall include: 1/2″ (13) thick fixed primary straining baffle with 3/8″ (10) holes and secondary 1/2″ (13) thick removable straining baffle with 3/8″ (10) holes, removable cross bar, securing bolt(s), stainless steel calibrated orifice plate, and steel powder epoxy coated non skid rectangular gasketed lid(s). |
No Rating |
Product Version: Unknown
52 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |
No Rating |
Product Version: Revit Architecture 2015
5917 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |
No Rating |
Product Version: Revit Architecture 2015
6705 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |
No Rating |
Product Version: Unknown
3787 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |
No Rating |
Product Version: Revit Architecture 2015
3403 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |

|
Product Version: Revit Architecture 2015
9841 Downloads
|
|
 |
Model LF174A Boiler Pressure Relief Valves are Lead Free* cast copper silicon alloy body safety relief valves for pressure protection only of all types of hot water heating boiler equipment. Pressure range is 50 to 150psi (3 - 10 bar) with corresponding high ratings from 2,459,000 to 14,370,000 BTU/hr. Female inlet and outlet connections. Sizes: 3/4in. - 2in. (20 - 50mm). The LF174A features Lead Free* construction to comply with Lead Free* installation requirements. It resists corrosive water conditions, sticking, and freezing, and it prevents water and sediment from being trapped in the seat. It is designed for emergency safety relief and shall not be used as an operating control. |
No Rating |
Product Version: Revit MEP 2014
211 Downloads
|
|
 |
Dining room set has eight pieces. All under the heading of dining room….. The dining table is 42”x64”, dining table leaf is 18”x42”, server is 18”x44”, buffet & china are 18”x56”, Captain’s & side chair 18”x18”. The split table 32”x42” is designed for adding leafs. All pieces are red oak. Offset varies from 16” to 24” Enjoy! |
No Rating |
Product Version: Revit Architecture 2015
1858 Downloads
|
|
 |
Series LF7 Lead Free* Dual Check Valves prevent the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at individual outlets. They have a Lead Free* cast copper silicon alloy body construction, two plastic replaceable check valves, and stainless steel springs. Series LF7 is designed for non-health hazard residential water system containment, continuous pressure applications. It is installed immediately downstream of the residential water meter, in a vertical or horizontal position. Check with local inspection authorities for installation requirements. Minimum Working Pressure: 10psi (69 kPa) Maximum Working Pressure: 150psi (10 bar). |
No Rating |
Product Version: Revit MEP 2014
149 Downloads
|
|
 |
Series 152A Process Steam Pressure Regulators are used in commercial, industrial, and institutional applications to regulate steam pressure in autoclaves, steam tables/irons, vulcanizers and large capacity process services. They are highly sensitive to reduced pressure changes. They have an iron body construction with NPT threaded female inlet and outlet connections, stainless steel strainer, laminated metal diaphragm, and sensitivity adjustment feature for critical flow. Series 152A offers full volume with minimum pressure drop and in-line serviceability. It is ideal for use on sterilizers, process lines, testing fixtures, and oil lines. Tight seating Model 152A-T available for dead end and liquid services. Maximum Supply Pressure: Up to 200psi (13.8 bar). |
No Rating |
Product Version: Revit MEP 2014
300 Downloads
|
|
 |
Series LF601 & LF601S Lead Free* cast copper silicon alloy Maxi-Flo Check Valves are used to prevent the effects of water hammer in the piping system. They feature a Lead Free* copper silicon alloy body, Viton disc, and integral copper silicon alloy seat. They have a low pressure drop and can be installed in a horizontal or vertical position. Model LF601 is available in sizes 1/4 to 1/2 in. (8 to 15mm) with threaded connections. Model LF601S is available in sizes 1/2 to 1 in. (15 to 25mm) with solder connections. Maximum Pressure: 250psi (17.24 bar) WOG non-shock @ 100°F (38°C). |
No Rating |
Product Version: Revit MEP 2014
125 Downloads
|
|
 |
AGRV_FURN_Bar2_吧檯組2
StandAlone Bar Table & Stool
Metric BarTableSet with DIM & Material parameters and dimension Guide
Visit our website AgileRevit.com for more families |
No Rating |
Product Version: Revit Architecture 2018
1802 Downloads
|
|
 |
The LF8 Series Hose Connection Vacuum Breakers permit the attachment of portable hoses to hose thread faucets and prevent the reverse flow of polluted water into the potable water supply due to backsiphonage. They have a copper silicon alloy body construction, stainless steel working parts, and a rubber diaphragm and disc. The LF8 Series is ideal for inside or outside health hazard installations requiring non-continuous pressure such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas, and general outside gardening uses. Check with local inspection authorities for installation requirements. Maximum Pressure:125psi (8.6 bar). |
No Rating |
Product Version: Revit MEP 2014
237 Downloads
|
|
 |
Series LFN250 Iron Body Water Pressure Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is suitable for water supply pressures up to 250psi (17.2 bar) and may be adjusted from 25 - 75psi(172 - 517 kPa). The standard setting is 50psi (345 kPa). All parts are quickly and easily serviceable without removing the valve from the line. The optional bypass feature permits the flow of water back through the valve into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main supply. The LFN250 features Lead Free* construction to comply with Lead Free* installation requirements. |
No Rating |
Product Version: Revit MEP 2014
409 Downloads
|
|
 |
Series 909RPDA Reduced Pressure Detector Assemblies prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 909RPDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of an epoxy-coated cast iron body with stainless steel trim, bronze gate valves, a pressure-differential relief valve, shutoff valves, and bronze ball-type test cocks. Series 909RPDA provides maximum flow at low pressure drop utilizing the "air-in/water-out" design principle for protection during emergency combined backsiphonage and backpressure conditions. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
645 Downloads
|
|
 |
Series LF26A Lead Free* Small Pressure Regulators are used in small general purpose applications to regulate pressure in piping systems using water and No. 2 fuel oil. They have a Lead Free* brass body construction with NPT threaded female inlet and outlet connections, 1/4 in. two-way low-pressure gauge port, aluminum spring cage, Buna-N stainless steel disc, reinforced Buna-N diaphragm, and tee handle adjustment. Options include Viton trim and slotted adjusting screw. Strainers are recommended. Series LF26A has an oversized orifice and is ideal for use on beverage dispensing and paint spraying equipment, ice cube machines, humidifiers, drinking fountains, and other small process applications. Maximum Working Pressure: 300psi (21 bar). |
No Rating |
Product Version: Revit MEP 2014
187 Downloads
|
|
 |
Series LF263A Lead Free* Small Pressure Regulators are used in small general purpose applications to regulate pressure in piping systems using water and No. 2 fuel oil. They have a Lead Free* brass body construction with NPT threaded female inlet and outlet connections, 1/4 in. three-way low-pressure gauge port, aluminum spring cage, Buna-N stainless steel disc, reinforced Buna-N diaphragm, and tee handle adjustment. Options include Viton trim and slotted adjusting screw. Strainers are recommended. Series LF263A has an oversized orifice and is ideal for use on beverage dispensing and paint spraying equipment, ice cube machines, humidifiers, drinking fountains, and other small process applications. Maximum Working Pressure: 300psi (21 bar). |
No Rating |
Product Version: Revit MEP 2014
122 Downloads
|
|
 |
Series 994DCDA Reduced Pressure Detector Assemblies prevent the reverse flow of fire protection system substances from being pumped or siphoned into the potable water supply. The 994DCDA incorporates a meter to detect ground leaks and unauthorized illegal taps, greatly reducing annual water expenses. It consists of a stainless steel body, stainless steel internal parts, thermoplastic check valves and a bottom-mounted relief valve. Series 994DCDA is half the weight of competitive designs, and its short lay length makes installation and maintenance simple and easy. It is ideal for installation on fire protection systems. Check with local water authorities for installation requirements. Maximum Working Pressure: 175psi (12.06 bar) |
No Rating |
Product Version: Revit MEP 2014
341 Downloads
|
|
 |
MIFAB® Series MI-SD____ sanitary epoxy coated inside and outside fabricated 10 gauge steel sand interceptor. Unit shall include: removable cross bar, four 3" (76) threaded vent connections, solid straining baffles, stainless steel calibrated orfice plate, securing bolt(s), sediment bucket with perforated baffle beside inlet, deep seal trap, sewer gas stopper, internal air relief by-pass, and steel powder epoxy coated non skid rectangular gasketed lid(s). |

|
Product Version: Unknown
215 Downloads
|
|