Series LF1170, LFL1170 Lead Free* Hot Water Temperature Control Valves are specifically designed for mixing hot and cold water on hot water supply systems. They can be used for a variety of applications to reduce the temperature of the hot water from the system, and are ideal for radiant heat applications. This series features a "double throttling" design which combines the control of the hot and cold water to provide a sensitive response to changes in water temperature passing through the mixing chamber. The LF1170 can be set to any temperature between 90°F and 160°F (60°F and 120°F for model LFL1170-M2) with flow rates as low as 0.5 gpm and as high as 23 gpm. The superior flow characteristics of this valve provide accurate temperature control to the requirements of ASSE 1017 across the rated flow range. These valves also provide additional safety as they restrict mixed water out to a drip upon loss of cold water supply to the valve. As an added feature, the LF1170, LFL1170 series incorporates integral check valves and filter washers in both the hot and cold water inlets to protect against cross flow. Available with threaded (-UT), solder (-US), PEX Quick-Connect (-QC) or CPVC connections. Maximum Pressure: 150psi (10 bar). Consisting of Lead Free* cast copper silicon alloy body construction. |

|
Product Version: Revit MEP 2014
599 Downloads
|
|
 |
Series LFSL100XL, LFL100XL, LFLL100XL and LFLLL100XL Lead Free* Extended Shank Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr. They feature an extended shank for installation on water heaters with extra thick insulation as well as a Lead Free* brass body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, and a test lever. Model LFSL100XL is suitable for water heaters with up to 1-3/4 in. (45mm) of insulation. Model LFL100XL is suitable for water heaters with up to 2 in. (51mm) of insulation. Model LFLL100XL is suitable for water heaters with up to 2-1/2 in. (64mm) of insulation. Model LFLLL100XL is suitable for water heaters with up to 3 in. (76mm) of insulation. Series LFSL100XL, LFL100XL, LFLL100XL and LFLLL100XL are ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
92 Downloads
|
|
 |
Series LF40L, LF40XL Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature a Lead Free* brass body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model LF40L has a short thermostat for installation directly in available tank tapings. Model LF40XL has an extension thermostat for installation in the hot water outlet within the allowable distance from the top of the tank. Series LF40L, LF40XL valves are ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
177 Downloads
|
|
 |
Series LFLL40XL, LFLLL40XL Extended Shank Automatic Reseating Temperature and Pressure Relief Valves are used in commercial water heater applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters. They feature an extended shank for installation on water heaters with extra thick insulation as well as a Lead Free* cast copper silicon alloy with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, tamper-resistant bonnet screws, automatic reseating feature, and test lever. Model LFLL40XL is available in sizes 3/4 and 1 in. (20 and 25mm). Model LFLLL40XL is available in size 3/4 (20mm) with an extra long extended shank. Series LFLL40L, LFLLL40XL valves are ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
91 Downloads
|
|
 |
Series LFN250 Iron Body Water Pressure Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is suitable for water supply pressures up to 250psi (17.2 bar) and may be adjusted from 25 - 75psi(172 - 517 kPa). The standard setting is 50psi (345 kPa). All parts are quickly and easily serviceable without removing the valve from the line. The optional bypass feature permits the flow of water back through the valve into the main when pressures, due to thermal expansion on the outlet side of the valve, exceed the pressure in the main supply. The LFN250 features Lead Free* construction to comply with Lead Free* installation requirements. |
No Rating |
Product Version: Revit MEP 2014
416 Downloads
|
|
 |
Rain falling under boxed in surround. Makes for a nice water feature. 11'-10" X 10'-8". |

|
Product Version: Revit Architecture 2018
17582 Downloads
|
|
 |
Series LF210-5 Lead Free* Automatic Gas Shutoff Valves are used in gas water heater applications to protect against overheating water in the domestic hot water supply heating system. It is an immersion-type valve that automatically shuts off the gas supply to the heater if the temperature reaches 210°F (99°C). It is a self-contained device that consists of Buna-N disc-to-metal seating, manual reset button to reopen the valve after an automatic shutoff, trip latch assembly, and stainless steel spring seats to close the valve at a controlled temperature. A thermostat with extension tube operates a trip latch in response to water temperature. Design certified by CSA. Models LFL210-5 M2 and LFLL210-5 M2 feature extended shanks for use with water heaters containing extra thick insulation up to 2 1/2 in. |
No Rating |
Product Version: Revit MEP 2014
288 Downloads
|
|
 |
Water meter as used by utility network operators, Drainlayers and Plumbers in NZ when connecting potable cold water reticulation to residential and small commerical and industrial buildings for new build work, refurbishment and as the local regulations change to require water meters in more local government jurisdictions.
Manufactured by Arthur D Riley of NZ, this WTD-DRA70 water meter has the "extra tall manifold" (in ground case)
Revit face based model.
Can easily be hosted on Building Pad with a small area in the topography
CBI (NZ) Liquid 71-21 for cold potable water reticulation systems.
Materials include copper for supply in/out, water meter lid (green plastic) and water meter case (generic ABS plastic).
MEP connections for supply In/OUT (25 mm).
Revit 2018 |
No Rating |
Product Version: Unknown
1896 Downloads
|
|
 |
Series LF1L, LF1XL Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 15,000 BTU/hr. They feature an all Lead Free* copper silicon alloy body with NPT threaded male inlet and NPT threaded female outlet connections, unique thermostat with special thermo-bonded coating, and test lever. Series LF1L, LF1XL are CSA listed. Model LF1L has 2 in. (50mm) thermostat and a test lever. Model LF1XL has an extension thermostat. Temperature Relief: 210 degreeF (99 degreeC). Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
99 Downloads
|
|
 |
Series LF1L, LF1XL Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 15,000 BTU/hr. They feature an all Lead Free* copper silicon alloy body with NPT threaded male inlet and NPT threaded female outlet connections, unique thermostat with special thermo-bonded coating, and test lever. Series LF1L, LF1XL are CSA listed. Model LF1L has 2 in. (50mm) thermostat and a test lever. Model LF1XL has an extension thermostat. Temperature Relief: 210 degreeF (99 degreeC). Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
121 Downloads
|
|
 |
Series LF1L, LF1XL Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 15,000 BTU/hr. They feature an all Lead Free* copper silicon alloy body with NPT threaded male inlet and NPT threaded female outlet connections, unique thermostat with special thermo-bonded coating, and test lever. Series LF1L, LF1XL are CSA listed. Model LF1L has 2 in. (50mm) thermostat and a test lever. Model LF1XL has an extension thermostat. Temperature Relief: 210 degreeF (99 degreeC). Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
102 Downloads
|
|
 |
Series LF100XL Temperature and Pressure Relief Valves are used in water heater and hot water storage tank applications to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr. They feature a Lead Free* copper alloy body with NPT male inlet and NPT female outlet connections, unique thermostat with special thermo-bonded coating, and a test lever. Model LF100XL-8 is also available with 8 in. (200mm) extension thermostat. Series LF100XL is ASME rated and CSA listed. Temperature Relief: 210 degreeF (99 degreeC). Pressure Relief Range: 75 to 150psi (5.2 to 10.3 bar). Standard Pressure Settings: 75, 100, 125, or 150psi (5.27, 7.03, 8.79, or 10.55 bar). |
No Rating |
Product Version: Revit MEP 2014
127 Downloads
|
|
 |
Series 1070 and P1070 LavSafe thermostatic faucets feature an advanced thermal actuator to provide the latest in thermal protection. The single-lever cartridge, with integral ceramic discs, provides both temperature and volume control. LavSafe automatically mixes hot and cold water to deliver pre-set water within a specific range. In the event of cold water failure, the thermal actuator virtually shuts off the flow of hot water. LavSafe is listed to ASSE 1070, IAPMO cUPC, and NSF 61 Section 9 Annex G. |
No Rating |
Product Version: Revit MEP 2014
795 Downloads
|
|
 |
Series G1070 and GP1070 thermostatic gooseneck faucets feature an advanced thermal actuator to provide the latest in thermal protection. The single-lever cartridge, with integral ceramic discs, provides both temperature and volume control. LavSafe automatically mixes hot and cold water to deliver pre-set water within a specific range. In the event of cold water failure, the thermal actuator virtually shuts off the flow of hot water. LavSafe is listed to ASSE 1070, IAPMO cUPC, and NSF 61 Section 9 Annex G. |
No Rating |
Product Version: Revit MEP 2014
644 Downloads
|
|
 |
This is a dumping bucket for a water park or splash pad. |

|
Product Version: Revit Architecture 2016
3424 Downloads
|
|
 |
Similiar to flowers seen in a water park or splash pad. |

|
Product Version: Revit Architecture 2016
8643 Downloads
|
|
 |
Series LF123LP Water Pressure Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is suitable for water supply pressures up to 200psi (13.8 bar) and may be adjusted from 10 - 30psi (69 - 207 kPa). The standard setting is 30psi (207 kPa). All parts are quickly and easily serviceable without removing the valve from the line. The LF123LP features Lead Free* construction to comply with Lead Free* installation requirements. |
No Rating |
Product Version: Revit MEP 2014
294 Downloads
|
|
 |
Series LF560 Mini Water Pressure Reducing Valves are designed to reduce incoming water pressure to a sensible level to protect plumbing system components and reduce water consumption. This series is ideal where a small, economical package is required such as on special industrial process applications, miscellaneous plumbing applications, and OEM equipment. Series LF560 is suitable for water supply pressures up to 300psi (21 bar). The LF560 features Lead Free* construction to comply with Lead Free* installation requirements. |
No Rating |
Product Version: Revit MEP 2014
151 Downloads
|
|
 |
Parametric Water Tank with Parametric water inside. I tried to work out the water and tank volume calculations but gave up when I relaized that I and Revit can't do math very well |
No Rating |
Product Version: Revit Architecture 2011
12686 Downloads
|
|
 |
The MI-100 is engineered for equal distribution of water to all ports. It’s the perfect solution to keep sewer gas from entering the building from seldom used floor drains. The MI-100 can be located anywhere in the water supply and is engineered to permit the building owner to adjust the frequency and amount of water delivery through a timer and stainless steel solenoid valve. A manifold ensures that a minimum of 2 ounces of water are delivered to every port over a twenty-four hour period. The unit must be mounted 12” above the finished floor for every 20’ of water supply line. The MI-100 can be installed with a cabinet cover. The system is capable of priming from 1 to 30 floor drain traps. The MI-100 is practical to serve many floor drain traps in infrequently used buildings such as convention centers and sports facilities. The MI-100 is made of lead free materials that touch water. |
No Rating |
Product Version: Unknown
202 Downloads
|
|
 |
Very Long Pond, but dimensions can be adjusted in family editor. |

|
Product Version: Revit Structure 2018
5284 Downloads
|
|
 |
Series 757DCDA, 757NDCDA Double Check Detector Assemblies prevent the backflow of pollutants that are objectionable but not toxic, from entering into the potable water supply. Compact housings consist of two independently operating tri-link check valves, two shutoff valves, and four test cocks. They feature a stainless steel housing and sleeve and are 70% lighter than traditional designs. Series 757, 757N is designed for non-health hazard applications and may be installed under continuous pressure service to protect against both backpressure and backsiphonage. This Series is used primarily on fire sprinkler lines when it is necessary to monitor unauthorized use of water. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
576 Downloads
|
|
 |
Series 774 Double Check Valve Assemblies prevent the backflow of polluted water from entering into the potable water supply. They have a compact construction and short lay length, ideal for retrofit installations. They feature a lightweight stainless steel body and low head loss. Series 774 is ideal in applications identified by local authorities as non-health hazard. Maximum Working Pressure: 175psi (12.06 bar). |
No Rating |
Product Version: Revit MEP 2014
520 Downloads
|
|
 |
A parametric water boiler from Heliotek (Bosch), models MK(P) 200, 300, 400, 500 and 600(Lts). For use with solar thermal collectors. Also has a electricl conector for a 2500W internal electrical resistance heating.
Modeled by dufbp, made by Bosch.
Country: Brazil |

|
Product Version: Revit Architecture 2017
5610 Downloads
|
|
 |
A solar heater is a device that uses heat from the sun to heat a substance, in this case water. Its most common use is to heat water for use in pools and health services (showers, laundry or dishes etc.) Both in domestic environments such as hotels.
Are simple and sturdy, they can have a lifespan of up to 20 years without major maintenance.
In many climates, a solar water heater can reduce energy consumption used to heat water. This decrease can be up to 80% in gas consumption. We recommend cleaning the collector every 4 to 6 months to increase their efficiency and lifespan.
The efficiency of capturing solar energy is very high solar heaters.
Un calentador solar es un aparato que utiliza el calor del sol para calentar alguna sustancia, en este caso agua. Su uso más común es para calentar agua para uso en albercas y servicios sanitarios (duchas, lavado de ropa o trastes etc.) tanto en ambientes domésticos como hoteles.Son sencillos y resistentes, pueden tener una vida útil de hasta 20 años sin mayor mantenimiento.
En muchos climas un calentador solar puede disminuir el consumo energético utilizado para calentar agua. Tal disminución puede llegar a ser de hasta 80% en consumo de gas. Se recomienda limpiar el colector cada 4 o 6 meses para aumentar su eficiencia y vida útil.
La eficiencia para captar la energía solar es muy elevada en los calentadores solares. |

|
Product Version: Revit Architecture 2013
20764 Downloads
|
|
 |
Wellington City Council water Toby.
Street - in ground footpath mounted, old style cast steel manifold/case and hinged lid , which contains the below ground mains pressure (town supply/Utility reticulation) cold potable water supply Valve, to Residential, light commerical and light industrial properties.
Utility Network operator Toby case only - Wellington Water.
CBI (NZ) Liquid 71-21 - cold potable water reticulation systems.
Material for case and lid.
Generic model, no MEP connections.
Revit 2018
|
No Rating |
Product Version: Unknown
476 Downloads
|
|
 |
Series LF127W High Capacity Water Pressure Reducing Valves are used in commercial and industrial applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. They have a Lead Free* bronze body construction with NPT threaded inlet and outlet connections, replaceable stainless steel seat, and high temperature resisting interchangeable diaphragm chamber. Maximum Working Pressure: 175psi (12.1 bar), Adjustable Reduced Pressure Range: 25 to 100psi (1.7 to 7 bar). |
No Rating |
Product Version: Revit MEP 2014
191 Downloads
|
|
 |
Series LF127W High Capacity Water Pressure Reducing Valves are used in commercial and industrial applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. They have a Lead Free* bronze body construction with NPT threaded inlet and outlet connections, replaceable stainless steel seat, and high temperature resisting interchangeable diaphragm chamber. Maximum Working Pressure: 175psi (12.1 bar), Adjustable Reduced Pressure Range: 25 to 100psi (1.7 to 7 bar). |
No Rating |
Product Version: Revit MEP 2014
119 Downloads
|
|
 |
Series LF223, LF223S Lead Free* High Capacity Water Pressure Reducing Valves are used in commercial, industrial, and institutional applications to reduce incoming water pressure to a predetermined level, thereby protecting downstream plumbing system components and reducing water consumption. Designed for easy accessibility and serviceability without removing the valve from the line. Available with NPT threaded female inlet and NPT female threaded outlet. Series LF223S comes with a strainer. Standard pressure setting is 50psi with an adjustable range of 25 ‒ 75psi (172 ‒ 517 kPa). |
No Rating |
Product Version: Revit MEP 2014
240 Downloads
|
|
 |
Series LFF127W Flanged High Capacity Water Pressure Reducing Valves are used in commercial and industrial applications to reduce incoming water pressure for protection of plumbing system components and to reduce water consumption. They have a triple-coated corrosion preventative Lead Free* iron body construction with flanged inlet and flanged outlet connections, replaceable disc, interchangeable diaphragm chamber, replaceable stainless steel seat, and stainless steel stem. Size 4 in. is tapped for a bypass line and an auxiliary regulator. Maximum Working Pressure: 175psi (12.06 bar), Adjustable Reduced Pressure Range: 25 to 100psi (1.7 to 7.0 bar). |
No Rating |
Product Version: Revit MEP 2014
210 Downloads
|
|